Automatic Chargers Series VAC-F
Automatic Chargers Series VAC-F II (Protection Class II)

Built-in chargers for fire fighting vehicles and intervention vehicles
according to DIN 14679

 FII Feuerwehr
 

The charger series VAC-F is designed for installation in the vehicle and complies with all regulations of the FNFW of the valid fire brigade standard DIN 14679 for charging and trickle charging of auxiliary batteries and starter batteries in intervention vehicles.

The units of series VAC-F II are equipped with a protective insulation (protection class II, 2-core mains cable), and connection of a protective conductor is not required. So, they can be applied universally. Special case: In case of a (mains) single installation in the vehicle in protection class II according to DIN 14679, supplement C, the electric mains cable of the unit can simply be replaced by the heavy H07RN-F cable, 2x2.5 mm², being prescribed in this case. The mains terminals in the unit are easily accessible.

Unit type Art.-
No.
Art.-
No.
PC II
Charging
Capacity
[V]/[A]
Battery
Capacity
[Ah]
No. of
Charging
Ports
Charging
Current
Distributor
No. of
Temp.-
Sensors
Mains
Voltage
[V AC]
Weight
[g]
Exe-
cution
12V                    
VAC 1215 F 3A 0470 0471 12 / 15  30 - 75 (150*)  2 + SP yes 1 230 1350 A/D
VAC 1230 F 3A 0476 0477 12 / 30 50 - 150 (300*)  2 + SP yes 1 230 1450 A/D
VAC 1250 F 3A 0482 - 12 / 50  85 - 250 (500*)  2 + SP yes 2 230 2450 B
VAC 1280 F 2A 0487 - 12 / 80  120 - 400 (800*)  1 + S + SP - 1 230 3900 C
24 V                    
VAC 2416 F 3A 0494 0495 24 / 16  30 - 80 (160*)  2 + SP yes 1 230 1450 A/D
VAC 2425 F 3A 0496 - 24 / 25  40 - 125 (250*)  2 + SP yes 2 230 2400 B
VAC 2440 F 2A 0498 - 24 / 40  66 - 200 (400*)  1 + S - SP - 1 230 3900 C
  * in case of stop periods of the vehicles >24 hours, acc. to DIN 14679
    SP: Signalling port +86 for motor locking while the vehicle is connected to mains 12V/0,4A
    S: Separate auxiliary charging port "S" for support charging and conservation of charge of the vehicle's starter battery (max. 2A)

Execution A/D
Dimensions *: 210 x 160 x 71 mm

Execution B
Dimensions *: 305 x 160 x 71 mm

Execution C
Dimensions *: 305 x 265 x 90 mm

VAC 12V A

Front | Back

VAC 12V B

Front

VAC 12V C

Front

  * Dimensions incl. mounting flanges, without connections
Go to top