Automatic Charger VAC 2425 M 3A

Article-No. 0459

   Blaulicht  Offroad

 Boot

VAC 24V B

Charging Programs:

1  2  3  5

Technical Features:

BR  DC  Equ  FB  Kap  LV

PL  SR  TK  TS  VF  Tropfen

Charging Options:

Batterien 2S

1 to 2 Supply Batteries or
1 to 2 Starter Batteries or
1 Supply Battery and 1 Starter Battery

Front

Description

  • Charging programs No. 1, 2, 3 and 5 (gel, AGM, acid, start) adjustable to the battery type
  • Outstanding charging technology
  • The charging voltage is exempt from peaks, and it is controlled in such a way, that overcharging is excluded
  • Integrated charging current distributor with 2 main charging ports, each with max. current and output capacity
  • For mixed operation with 1 supply and 1 starter battery, a separate starter charging program can be adjusted at the built-in charging current distributor
  • If required, the starter battery can also be charged with full charging current (short stop period of the vehicle)
  • Additional auxiliary charging port "S" for support charging and trickle charge of a further starter battery (max. 4 A) or as signalling port +86 for motor locking while the vehicle is connected to mains
  • All-automatic continuous operation for permanent readiness for use of the vehicle
  • Precise battery temperature compensation, temperature sensor(s) is (are) included in the standard delivery
  • Equalization function (the characteristic line IUIU can be activated manually for compensation charging of the cells)
  • Intelligent microprocessor control observing the simultaneous supply of consumers
  • Battery regeneration in case of extended stop periods twice a week
  • Compensation of the voltage loss on the charging cables ensuring exact observation of the charging voltage rates
  • Separation of the batteries in case of power failure, overheating, incorrect behaviour (safety relay for each charging port)
  • Adjustable silent run function (reduction at night)
  • Power pack function allows continued operation of the consumers and preservation of data, such as in case of battery replacement
  • The electronic system is protected against humidity
  • Variable fitting position
  • 4 Battery capacity rates can be adjusted (16 charging programs in total)
  • 2 inputs, each, for sensor (sense) lines and battery temperature sensors
  • The mains/charging capacity can be reduced in case of low capacity or restricted power supply, such as in case of weakly protected country current supply , generator operation etc. (power limit function)

Technical Details

 Charging Capacity in [V]/[A] 24 / 25
 Nominal Operating Voltage (AC) in [V] 230
 Operating Voltage Range (AC) in [V] 190 - 265 (Full Charging Capacity)
 Power Consumption (AC) in max. [W] 830
 Sinusoidal Power Factor Correction (CosPhi = 1) yes
 Nominal Battery voltage (DC) in [V] 24
 Battery Capacity in [Ah] 46 - 290
 Charging Current in [A] 25
 Auxilary Charging Port "S" in [A] 4
 Characteristic Line of Charging IU1oU2
 Voltage limitation during all charging modes and programs [V] 30
 Ripple Factor Voltage in [mV] rms < 50
 Number of Charging Ports 2 + S
 Mounting Position of Unit any
 Temperature Range [°C] -20 to +45
 Protection Class/System of Protection I / IP 21
 Dimensions (WxDxH) in [mm] - Dimensions incl. mounting flanges, without connections
305 x 71 x 160
 Weight in [g] 2400
 Mark of conformity (CE) EN 60335-2-29
 Ambient Conditions, Humidity of Air:  max. 95 % RH, No Condensation
 Delivery Scope: Mains supply cable, 2 Temperature Sensors, Operating Manual

Charging Programs

1 „Gel“: Charging Program for Gel Batteries, Characteristic Line IU1oU2oU3
Adapted to closed, gas-tight gel/dryfit batteries with determined electrolyte, which are generally requiring a higher charging voltage level and longer dwell times U1 to achieve short charging times with particularly high capacity storage and to avoid total discharge. Also recommended for EXIDE MAXXIMA a high-current battery in AGM filament technology.

2 „AGM“: Charging Program for AGM/Fleece Batteries, Characteristic Line IU1oU2oU3
Adapted to charging closed, gas-tight AGM (absorbed glass mat) batteries and batteries in lead-fleece technology requiring a particularly high level U1 with adapted dwell times for full charging and after that a moderate level U2 for trickle charge (round cell and plate technology).

3 "DIN 0510“: Charging Program for Lead, Acid/Lead-Acid Batteries, Characteristic Line IU1oU2oU3
General characteristic line DIN for charging and conservation to charge of open and closed lead storage batteries with removable cell plugs and possibility of acid level control and acid level correction (maintenance). Also suitable for recently developed, closed battery types (low-antimonous, with lead-silver alloy, calcium etc.) with low and very low water consumption.
Allows short charging times with high level U1, high charging factor and high acid mixing, even during stationary application (acid accumulation) of "wet" drive, lighting, solar, heavy duty and standard batteries.

5 „MOTOR“: Charging Program for Lead, Acid/Lead-Acid Batteries, Characteristic Line IU1oU2oU3 Characteristic line similar to dynamo/generator for mobile application (acid accumulation) with particularly low maintenance (battery gassing, water consumption). Charging and conservation of charge of starter batteries in intervention vehicles, according to a customary suggestion of the Standard Committee Fire Protection (FNFW). For conventional, standard starter batteries, starter batteries being "absolutely maintenance-free", "maintenance-free according to EN", "maintenance-free according to DIN", "maintenance-free", "lowmaintenance".

Technical Features

BR Automatic battery regeneration   DC Power pack function (battery replacement)
Equ Equalization function
(compensation charging of the cells)
  FB Connection remote control / remote indicator
Kap Battery capacity (size) adjustable   LV Charging current distributor
for one or several batteries
PL Power limit function
(Reduction of the mains/charging capacity)
  SR Silent run funktion (reduction at night)
TK Temperature compensation   TS Temperature sensor is included
in the standard delivery
VF Voltage sensor
(in case of very long charging cables)
  Tropfen  Electronic system humidity-proof

Downloads

Anleitung Katalog

Accessories

Fernbedienung S Ladegeraete 2075

       
Betriebs Fernanzeige IP67 Batterie-Status-Anzeige 2082

Remote Control S (Art. 2075)

Remote Indicator IP67 (Art. 2081)

Charger State Monitor IP67 (Art. 2082)

Facebook Instagram xing LinkedIn YouTube twitter