Battery ControllersUndervoltage Protection for Board Battery and Starter Battery |
|
|
|
The VOTRONIC units Battery Protector 40 and Battery Protector 100 are connected between supply battery and consumers, and they are suitable for all types and brands of lead batteries (acid, gel, AGM). The units protect the battery from dangerous total discharge and the consumers and equipment from undervoltage and overvoltage. Apart from that, they can be used as remote-controlled battery main switch by means of an external switch.
Unit Type |
Art.- No. |
Operating Voltage [V] |
Switching Current Cont./Short-time [A] |
Switching Threshold Under- voltage [V] |
Reset Point Under- voltage [V] |
Over- voltage OFF/ON [V] |
Weight [g] |
Battery Protector 40 | 3075 | 12 | 40 / 60 | 10.7 | 12.5 | 15.5 / 15.0 | 97 |
Battery Protector 40 Motor | 3073 | 12 | 40 / 60 | 11.8 | 12.8 | 15.5 / 15.0 | 97 |
Battery Protector 40 / 24 | 6075 | 24 | 40 / 60 | 21.4 | 25.0 | 31.0 / 30.0 | 97 |
Battery Protector 40 / 24 Motor | 6073 | 24 | 40 / 60 | 23.6 | 25.6 | 31.0 / 30.0 | 97 |
Temperature Range: | -20 / +50°C | ||||||
Dimensions (W x H x D) | 90 x 38 x 60 mm (incl. mounting flanges, without connections) | ||||||
Mark of Conformity: | CE, E Test (EMV/Automotive Regulations) | ||||||
Delivery Scope: | Operating Manual |
Unit Type |
Art.- No. |
Operating Voltage [V] |
Switching Current Cont./Short-time [A] |
Switching Threshold Under- voltage [V] |
Reset Point Under- voltage [V] |
Over- voltage OFF [V] |
Weight [g] |
Battery Protector 100 |
3078 | 12 and 24 | 100 / 150 | 10.6 / 11.5 / 11.8 1 9.5 - 12.2 1,2 |
12.4 / 12.5 / 12.8 1 / 12.5 1,2 |
15.5 1 | 175 |
1 In case of 24 V operation values x 2 2 Automatic Switching Threshold | |||||||
Dimensions (W x H x D) | 10, x 35 x 89 mm (incl. mounting flanges) | ||||||
Mark of Conformity: | CE, E Test (EMV/Automotive Regulations) | ||||||
Delivery Scope: | Operating Manual, Cover for battery connections | ||||||
Temperature Range: | -20 / +50°C |
Operation as Battery Protector:
Operation as Switch Unit:
Unit Type |
Art.- No. |
Operating Voltage [V] |
Switching Current Cont./Short-time [A] |
Switching Threshold Under- voltage [V] |
Reset Point Under- voltage [V] |
Over- voltage OFF/ON [V] |
Weight [g] |
Battery Protector 300 |
3084 | 12 and 24 | 300 / 680 | 10.6 / 11.5 / 11.8 1 9.5 - 12.2 1,2 |
12.4 / 12.5 / 12.8 1 / 12.5 1,2 |
15.5 / 15.0 1 |
680 / 90 |
1 In case of 24 V operation values x 2 2 Automatic Switching Threshold | |||||||
Dimensions (W x H x D) | Relay: 105 x 62 x 57 mm / Electronic: 90 x 60 x 33 (incl. mounting flanges, without connections) | ||||||
Mark of Conformity: | CE, E Test (EMV/Automotive Regulations) | ||||||
Delivery Scope: | Operating Manual | ||||||
Temperature Range: | -20 / +50°C |
According to DIN EN 1789 for intervention vehicles
The VOTRONIC Start Alarm 124 is an alerter with audible alarm (beeper) and visual alarm (LED) for the starter battery of intervention vehicles with only one battery circuit (according to DIN EN 1789, paragraph 4.3.2). The alarm shall warn the driver early of a battery, which is not capable to start.
An additional horn or similar alarm device can be connected to a terminal (PNP, plus output, max. 0.5 A). The reset to normal operation is effected automatically, as soon as the motor is running again. The unit is suitable for 12 V and 24 V operation and for all types and brands of lead batteries. The electronic system is protected against humidity; the connection is made in the rear terminal box.
The own consumption is below 3 mA (according to EN 13976). The intelligent electronic evaluation of the Start Alarm 124 avoids indication errors, such as in case of voltage drops.
Unit Type |
Art.- No. |
Operating Voltage [V] |
Switching Current [A] |
Switching Threshold Undervoltage [V] |
Temperature Range [°C] |
Weight [g] |
Start Alarm 124 |
0161 | 12 und 24 | 0,5 | 11.7...11.9 1 | -20 / +50 | 30 |
1 In case of 24 V operation values x 2 | ||||||
Dimensions (W x H x D) | 70 x 17 x 36 mm (incl. mounting flanges, without connections) | |||||
Mark of Conformity: | CE, E Test (EMV/Automotive Regulations) | |||||
Delivery Scope: | Operating Manual |