Input IN Starter Battery "II" |
|
Nominal Voltage Battery |
24 V |
Recomm. Battery Capacity min. |
50 Ah |
Power Consumption max. |
450 W |
Current Draw (at lowest input voltage) max. |
18 A |
Current Consumption during Stand-by |
0.09 A |
Current Consumption OFF (K1.15/D+ without Signal) |
< 3 mA |
Overvoltage Disconnection EURO 6+ |
32.20 V |
Output OUT Board Battery "I" |
|
Nominal Voltage Battery |
12 V - 13.3 V |
Battery Capacity, recommended/up to |
50-170/220 Ah |
Charging Current Main Charging, Phase I, 8 V up to U1, 0-15 h |
25 A |
Charging/Floating/Load Current, controlled, Phase U1-U2 |
0 - 25 A |
Selectable Charging Programs AGM/Gel/Lead Acid, LiFePO4 |
4 |
Minimum Battery Voltage for Charging Start |
0 V |
Prelim. Charg. Current (deeply discharged battery) |
12.5 A (0-8 V) |
Reverse Current from Battery, OFF (K1.15/D+ without Signal) |
0.000 A |
Reset Voltage AGM-Gel-Lead Acid/LiFePO4 (30 sec) |
12.8 V/13.4 V |
Limit of Charging Voltage (Consumer Protection) |
15.00 V |
External Overvoltage Disconnection (20 sec.) |
15.50 V |
Ripple Factor Voltage |
< 30 mV rms |
Input for Battery I Temperature Sensor |
yes |
Charging Timer |
3-fold |
Safety Protect. ag. Reverse Batt./Short Circuit/Back Discharge |
yes |
Safety Timer per Charging Phase I /U1 |
yes |
EBL START In, Measuring Input/Charging Port |
--- |
Charging/Trickle Charging for Starter Battery 12V |
--- |
Overcharge Protection |
--- |
Safety Protect. ag. Reverse Batt./Short Circuit/Back Discharge |
--- |
Fitting Position of Unit |
any |
Temperature Range |
-20/+45° C |
Speed-controlled, Temperature-controlled Fan |
yes |
Gradual Reduction of Charging Capacity at Overtemperature |
yes |
Safety Disconnection in Case of Overheating |
yes |
System of Protection |
IP21 |
Weight |
1350 g |
Dimensions, incl. Mounting Flanges |
245 x 160 x 71 mm |
Ambient Conditions, Humidity of Air |
max. 95 % RH, no condensation |
Delivery Scope: Operating Manual, Temperature Sensor |
|